LARQuickCODlab
Bench-top laboratory COD analyser using 1,200 °C thermal oxidation to determine chemical oxygen demand in three minutes, without reagents or catalysts.
The QuickCODlab brings the high-temperature method used for on-line COD monitoring into the laboratory. Following ASTM D6238-98 but operating at 1,200 °C instead of the conventional 900 °C, the analyser oxidises all organic compounds without catalysts, hazardous chemicals or corrosive reagents. The sample is injected directly into the reactor and the oxygen consumed is measured with an O2 gas detector.
A complete measurement takes about three minutes, so triplicate results are possible in under ten minutes compared with the hours required by the standard dichromate procedure. A precision syringe with a thumb-wheel dose adjustment and spring-loaded plunger removes operator variation, and no pre-filtration is needed, keeping the sample representative.
Five pre-defined ranges cover 100, 200, 1,000, 3,000 and 10,000 mg/L COD, and user-defined ranges can be stored and recalled for laboratories running samples from many different sources. Salt concentrations up to 10 g/L are handled as standard, and up to 300 g/L sodium chloride with the high-salt furnace, without dilution.
Features and benefits
- Chemical-free, reagent-free COD analysis
- Results in three minutes
- Determination of the real oxygen demand
- Highest combustion temperature available (1,200 °C)
- No filtration and no memory effects
- Excellent chloride acceptance
- Very low maintenance and operational costs
Applications
Industrial effluent monitoring and influent load monitoring at municipal wastewater treatment works.
Specifications
| Measurement technique | Combustion, ASTM D6238-98 at 1,200 °C |
|---|---|
| Measuring ranges | 1–100, 10–200, 100–1,000, 1,000–3,000 and 2,000–10,000 mg/L COD; user-configurable ranges available |
| Response time | 3 minutes |
| Sample injection | Manual precision syringe, 1–200 µL dose |
| Salt tolerance | Up to 10 g/L as standard; up to 300 g/L NaCl with high-salt furnace |
| Housing | Powder-coated steel IP 54 |
| Dimensions | 19.3 × 16.5 × 17.3 in (W × H × D) |
| Weight | 81.5 lb |
| Power supply | 115 / 230 VAC, 50/60 Hz |
| Safety | 2/6 A internal, 16 A external |
| Software | LAR QuickCODlab, Windows 7 or higher |
| Data interface | USB 2.0, LAN (optional) |
| Data output | Export as .csv file |
Options
- ▪ 60-vessel automatic sampler
- ▪ High-salt furnace up to 300 g/L NaCl
Enquire about the QuickCODlab
Tell us about your process, sample or monitoring requirement and we will recommend the right configuration. Attach your technical specification or tender document and an application specialist will respond.
- ▪ Application-matched configuration advice
- ▪ Datasheets, certificates and drawings
- ▪ Quotation with lead times
Related products

QuickTOCultra
High-temperature on-line TOC analyser combusting at 1,200 °C to determine true TOC in streams ranging from ultra-pure wa…

QuickTOCpurity
On-line TOC analyser for pure and ultra-pure water, determining TC, TOC, TIC and DOC in the low ppb range without cataly…

FlowSampler
LAR FlowSampler sample conditioning accessory for hot and wet sample extraction.
Need help choosing?
Request a quote, a brochure or application advice for this analyser system.